.. / download
<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="generic.xsl"?>
<!DOCTYPE dmodule>
<dmodule xmlns:dc="http://www.purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://www.s1000d.org/S1000D_4-0/xml_schema_flat/proced.xsd">
	<identAndStatusSection>
		<dmAddress>
			<dmIdent>
				<dmCode modelIdentCode="S1000DGUN" systemDiffCode="0" systemCode="00" subSystemCode="0" subSubSystemCode="0" assyCode="00" disassyCode="00" disassyCodeVariant="A" infoCode="142" infoCodeVariant="B" itemLocationCode="A"/>
				<language countryIsoCode="US" languageIsoCode="en"/>
				<issueInfo inWork="00" issueNumber="001"/>
			</dmIdent>
			<dmAddressItems>
				<issueDate day="17" month="08" year="2010"/>
				<dmTitle>
					<techName>Phun Gun</techName>
					<infoName>Unusual environment/weather</infoName>
				</dmTitle>
			</dmAddressItems>
		</dmAddress>
		<dmStatus issueType="new">
			<security securityClassification="01"/>
			<dataRestrictions>
				<restrictionInstructions>
					<dataDistribution>DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.</dataDistribution>
					<dataDestruction>DESTRUCTION NOTICE: Destroy by any means possible to prevent disclosure of contents or reconstruction of the document.</dataDestruction>
				</restrictionInstructions>
			</dataRestrictions>
			<responsiblePartnerCompany enterpriseCode="1L6T4">
				<enterpriseName>US Army Materiel Command (AMC) Logistics Support Activity (LOGSA)</enterpriseName>
			</responsiblePartnerCompany>
			<originator enterpriseCode="07GB6">
				<enterpriseName>BTAS COE</enterpriseName>
			</originator>
			<applic>
				<displayText/>
			</applic>
			<brexDmRef>
				<dmRef>
					<dmRefIdent>
						<dmCode modelIdentCode="S1000DGUN" systemDiffCode="0000" systemCode="00" subSystemCode="0" subSubSystemCode="0" assyCode="00" disassyCode="00" disassyCodeVariant="A" infoCode="022" infoCodeVariant="A" itemLocationCode="D"/>
					</dmRefIdent>
					<dmRefAddressItems>
						<dmTitle>
							<techName>Phun Gun</techName>
							<infoName>Business rules exchange data module</infoName>
						</dmTitle>
					</dmRefAddressItems>
				</dmRef>
			</brexDmRef>
			<qualityAssurance>
				<firstVerification verificationType="tabtop"/>
			</qualityAssurance>
		</dmStatus>
	</identAndStatusSection>
	<content>
		<procedure>
			<commonInfo>
				<commonInfoDescrPara>
					<title>Instructions</title>
					<!-- ***************************************************************************************************************
					**		
					**		Check to see if anything can be added to PMCS for unusual conditions.
					**		Replace, if possible, applicable references.
					**		
					 *******************************************************************************************************************-->
					<para>Refer to <dmRef>
							<dmRefIdent>
								<dmCode modelIdentCode="S1000DGUN" systemDiffCode="0" systemCode="00" subSystemCode="0" subSubSystemCode="0" assyCode="00" disassyCode="00" disassyCodeVariant="A" infoCode="200" infoCodeVariant="B" itemLocationCode="A"/>
							</dmRefIdent>
							<dmRefAddressItems>
								<dmTitle>
									<techName>Phun Gun</techName>
									<infoName>PMCS</infoName>
								</dmTitle>
							</dmRefAddressItems>
						</dmRef> for preventive maintenance checks and services to be made when the materiel is subjected to unusual conditions.</para>
					<!-- ***************************************************************************************************************
					**		
					**		Verify TM 38-750 is still active, include in References DM. TM 38-750 is not available (03/15/11)
					**		
					 *******************************************************************************************************************-->
					<para>Report any chronic failure of materiel resulting from subjection to extreme conditions in accordance with <externalPubRef>
							<externalPubRefIdent>
								<externalPubCode>TM 38-750</externalPubCode>
								<externalPubTitle>Army Equipment Records Procedure</externalPubTitle>
							</externalPubRefIdent>
						</externalPubRef>.</para>
				</commonInfoDescrPara>
			</commonInfo>
			<preliminaryRqmts>
				<!-- ***************************************************************************************************************
				**		
				**		Should the environmental conditions listed in the table below be included here?
				**		
				**		
				 *******************************************************************************************************************-->
				<reqCondGroup>
					<noConds/>
				</reqCondGroup>
				<reqSupportEquips>
					<noSupportEquips/>
				</reqSupportEquips>
				<reqSupplies>
					<supplyDescrGroup>
						<supplyDescr id="sup-00-00-00-142B-001">
							<name>Wiping rags (clean, dry)</name>
							<identNumber>
								<manufacturerCode>58536</manufacturerCode>
								<!-- ***************************************************************************************************************
								**		
								**		IAW MIL-STD-3031, inclusion of <partNumber> is prohibited :
								**			<partAndSerialNumber>
								**				<partNumber>A-A-531</partNumber>
								**			</partAndSerialNumber>
								**		
								 *******************************************************************************************************************-->
							</identNumber>
							<reqQuantity>AR</reqQuantity>
						</supplyDescr>
					</supplyDescrGroup>
				</reqSupplies>
				<reqSpares>
					<noSpares/>
				</reqSpares>
				<reqSafety>
					<noSafety/>
				</reqSafety>
			</preliminaryRqmts>
			<mainProcedure>
				<proceduralStep id="stp-00-00-00-142B-001">
					<para>Perform the applicable step(s) as follows:</para>
					<note>
						<notePara>Periodic disassembling may be necessary for drying purposes.</notePara>
					</note>
					<proceduralStep id="stp-00-00-00-142B-002">
						<para>For operations in extreme cold, perform the following steps:</para>
						<note>
							<notePara>Whenever a cold weapon is placed indoors, allow it to warm to room temperature. After cleaning, dry thoroughly including any condensation that has formed.</notePara>
						</note>
						<proceduralStep id="stp-00-00-00-142B-003">
							<para>In climates where the temperature is consistently below 0°F, it is necessary to prepare the materiel for cold-weather operation. The Phun Gun should be cleaned.</para>
						</proceduralStep>
						<proceduralStep id="stp-00-00-00-142B-004">
							<para>Operate the various controls through their entire range, at intervals, as required. This aids in keeping them from freezing in place and reduces the effort required to operate them.</para>
						</proceduralStep>
						<proceduralStep id="stp-00-00-00-142B-005">
							<para>Materiel not in use and stored outside must be protected with a proper cover.</para>
						</proceduralStep>
						<proceduralStep id="stp-00-00-00-142B-006">
							<para>See <externalPubRef>
									<externalPubRefIdent>
										<externalPubCode>FM 31-70</externalPubCode>
										<externalPubTitle>Basic Cold Weather Manual</externalPubTitle>
									</externalPubRefIdent>
								</externalPubRef> for further information on operations in the Arctic.</para>
						</proceduralStep>
					</proceduralStep>
					<proceduralStep id="stp-00-00-00-142B-007">
						<para>For operations in extreme heat, perform the following step:</para>
						<note>
							<notePara>In hot climates whether humid, dry, or sandy; daily care must be exercised. In hot, dry climates where dust and sand prevail, the weapon will be wiped dry.</notePara>
						</note>
						<proceduralStep id="stp-00-00-00-142B-008">
							<para>Perspiration contributes to corrosion, because it contains acids and salts. After handling Phun Gun, clean all surfaces with <internalRef internalRefId="sup-00-00-00-142B-001" internalRefTargetType="para"/>.</para>
						</proceduralStep>
					</proceduralStep>
					<proceduralStep id="stp-00-00-00-142B-009">
						<para>For operations in dusty and sandy areas, perform the following steps:</para>
						<note>
							<notePara>In hot climates whether humid, dry, or sandy; daily care must be exercised. In hot, dry climates where dust and sand prevail, the weapon will be wiped dry. When leaving sandy terrain, wipe rifle clean at once.</notePara>
						</note>
						<proceduralStep id="stp-00-00-00-142B-010">
							<para>Clean and keep thoroughly dry. Do not lubricate. Even a light coat of oil will attract foreign matter, especially sand and dust, a potential cause of mechanical breakdown. During disassembly and assembly operations, shield parts whenever possible.</para>
						</proceduralStep>
						<proceduralStep id="stp-00-00-00-142B-011">
							<para>When moving out of sandy terrain, clean as indicated.</para>
						</proceduralStep>
					</proceduralStep>
					<proceduralStep id="stp-00-00-00-142B-012">
						<para>For operations under rainy, humid conditions and salt water areas, perform the following step:</para>
						<note>
							<notePara>In hot climates whether humid, dry, or sandy, daily care must be exercised. In humid or rainy conditions, keep weapon clean when not in use.</notePara>
						</note>
						<proceduralStep id="stp-00-00-00-142B-013">
							<para>Inspect the materiel more frequently when operating in hot, moist areas.</para>
						</proceduralStep>
					</proceduralStep>
				</proceduralStep>
			</mainProcedure>
			<closeRqmts>
				<reqCondGroup>
					<noConds/>
				</reqCondGroup>
			</closeRqmts>
		</procedure>